[. . . ] [. . . ] (under Konica Minolta's test conditions)
Battery compartment
PU
® OX -300 LS
Designed using 3D CAD for doubled impact resistance !
(Compared with Konica Minolta's conventional model PULSOX-3 based on structural analysis using the finite element method)
PU
® OX -300 LS
Perfect fit on the wrist !
The contact surface is contoured to significantly improve stability during movement. The main unit weighs only 56 g (including the battery).
Wrist band (standard accessory)
Select from 4 types of optional probes
Finger Clip Probe SR-5C (0. 3 m)
The optimum probe can be selected from 4 types according to the application.
Spot Check Probe SP-5C (0. 5 m)
Personal Probe SD-5C/SD-5C (20) Package of 5 (0. 5 m)
For continuous measurements with the main unit worn on the wrist.
For face-to-face measurements in clinics or hospitals.
For single-patient use
Monitor Probe LM-5C (0. 3 m)
Extension Cable (optional) EC-300 (1 m)
(Example of Spot Check Probe SP-5C. )
For continuous measurements over a long period of time such as while sleeping.
Main specifications
For connecting the probe to the main unit to allow the length to extend.
Dual-wavelength pulse type (665nm/880nm) arterial blood oxygen saturation measuring instrument · Name: Oxygen Saturation Monitor · Model name: T-10 Functions: · Measuring range: SpO2: 0 to 100% SpO2 Pulse rate: 30 to 230 bpm · Accuracy: SpO2: ±2% SpO2 (70 to 100% range, 1S. D. ) Pulse rate: ±2 bpm (30 to 100 range) or ±2% of value (100 to 230 range) Display Display type: LED display Oxygen saturation (SpO2), Pulse rate, Pulse level meter (5 steps), Battery indication, Error messages indication Warning functions SpO2: Low SpO2 warning (flashing display), Battery indication (flashing when the battery is nealy empty), Error message indication Operating conditions temperature/humidity range 0 to 40°C (32 to 104°F); 30 to 85% relative humidity with no condensation atmospheric pressure/altitude range 700 to 1060hPa (altitude: 400 to 3000m) Storage conditions temperature/humidity range 10 to 60°C (14 to 140°F); 10 to 95% relative humidity with no condensation atmospheric pressure/altitude range 700 to 1060hPa (altitude: 400 to 3000m) Power 1 AAA-size battery: 1. 5V , 100mW (Service life under continual usage: approx. Using improper batteries may cause a fire or electric shock.
3-91, Daisennishimachi, Sakaiku, Sakai, Osaka 590-8551, Japan Konica Minolta Sensing Americas, Inc. Phone: 888-473-2656 (in USA), 201-236-4300 (outside USA) FAX: 201-785-2480 Rm. 29A, K Cross Region Plaza, No. 899 Lingling Rd. , Shanghai, China Phone: +86-021-5489 0202 FAX: +86-021-5489 0005 10, Teban Gardens Crescent, Singapore 608923 Phone: +65 6563-5533 FAX: +65 6560-9721
©2005 KONICA MINOLTA SENSING, INC.
9242-4863-10 AGMBPK 3